Error: for component with CLSID {1E04F3CE-54BD-4247-967C-56D3C6C4D931}

Active Directory
6.5 and older
7.0-8.5
https://kb.netwrix.com/1153
Copy Article URL Copied

Netwrix Auditor report contains the warning:
‘‘Change analysis completed with error: Error saving current Active Directory snapshot: Retrieving the COM class factory for component with CLSID {1E04F3CE-54BD-4247-967C-56D3C6C4D931} failed due to the following error: 80040154″



Please perform the following steps:

  1. Navigate to the Netwrix Auditor installation folder. For example, C:Program Files (x86)NetWrixAD Change Reporter Full Version.
  2. Open a command prompt in this folder (SHIFT + right-click a folder and select Open command window here).
  3. Type regsvr32 addump.dll and press Enter.
  4. The following message should appear: “DllRegisterServer in addump.dll succeeded“.
Go Up